Structural retrofitting of buildings: Turnbuckle exterior post tensioning
College
Gokongwei College of Engineering
Department/Unit
Civil Engineering
Document Type
Conference Proceeding
Source Title
IABSE Conference, Nara 2015: Elegance in Structures - Report
First Page
400
Last Page
401
Publication Date
1-1-2015
Abstract
Nowadays the problem of aging and deterioration of reinforced concrete buildings are eminent and due to excessive loading, the flexural performance and serviceability of structures are affected. The turnbuckle exterior post tensioning (T-EPT) is proposed as a retrofitting method wherein it was proven experimentally that it can be able to improve the serviceability and load carrying capacity of beams. A computer modeling method was developed to simulate the application of the T-EPT to full scale beam sections to determine its effectiveness with different cases. Different T-EPT configurations were modeled and the most efficient design that can be applied to structures was determined. Overall the T-EPT was effective in improving the serviceability and load carrying capacity of reinforced concrete beams.
html
Recommended Citation
Lejano, B. A., & Toral, K. (2015). Structural retrofitting of buildings: Turnbuckle exterior post tensioning. IABSE Conference, Nara 2015: Elegance in Structures - Report, 400-401. Retrieved from https://animorepository.dlsu.edu.ph/faculty_research/32
Disciplines
Civil Engineering
Keywords
Buildings, Reinforced concrete; Buildings—Retrofitting