Determination of lead (Pb2+) by anodic stripping voltammetry based on [Ru(NH3)6]3+/Nafion modified electrodes
College
College of Science
Department/Unit
Physics
Document Type
Article
Source Title
Journal of New Materials for Electrochemical Systems
Volume
17
Issue
4
First Page
205
Last Page
208
Publication Date
1-1-2014
Abstract
Chemically modified [Ru(NH3)6]3+ doped Nafion→ thin film was fabricated on indium tin oxide (ITO) coated glass electrodes by using the drop-coating method to detect heavy metal ions of Pb(II) in de-ionized water analyte solution via anodic stripping voltammetry (ASV). This study also determined the effect of varying the concentration of the mediator ([Ru(NH3)6]3+) on the detection of the said heavy metals. The redox mediator Ru(NH3)6]3+ used in the study was effectively incorporated and immobilized within the Nafion modified electrodes. Lead concentration in the electrolyte solution and the concentration of the redox mediator was varied to control the properties of the fabricated electrodes which utilized for heavy metal detection through ASV. The conducting properties of ITO electrodes were enhanced with the deposition of Nafion→ attaining minimal interference. The stripping current peaks increased with the concentration of the heavy metal present in the solution as well as with the mediator concentration. © J. New Mat. Electrochem. Systems.
html
Digitial Object Identifier (DOI)
10.14447/jnmes.v17i4.390
Recommended Citation
Palisoc, S. T., Natividad, M. T., De Vera, P., & Tuason, B. B. (2014). Determination of lead (Pb2+) by anodic stripping voltammetry based on [Ru(NH3)6]3+/Nafion modified electrodes. Journal of New Materials for Electrochemical Systems, 17 (4), 205-208. https://doi.org/10.14447/jnmes.v17i4.390
Disciplines
Physics
Keywords
Heavy metals; Anodic stripping voltammetry; Electrochemistry
Upload File