Development of charge level monitoring of lead-acid battery bank for PV system using fuzzy logic in LabView
Added Title
IEEE International Conference on Humanoid, Nanotechnology, Information Technology, Communication and Control, Environment, and Management (11th : 2019)
HNICEM 2019
College
Gokongwei College of Engineering
Department/Unit
Mechanical Engineering
Document Type
Conference Proceeding
Source Title
2019 IEEE 11th International Conference on Humanoid, Nanotechnology, Information Technology, Communication and Control, Environment, and Management, HNICEM 2019
Publication Date
11-1-2019
Abstract
This paper presents a charge level monitoring system for lead acid battery bank in Solar Panel setup. The research implements the approximate linear relationship between the charge level and the current-voltage for lead acid batteries. Prediction method utilizes is the objective fuzzy logic approach. Both the interphase of the instrument and the fuzzy system together with the fuzzy rule system were created using LabView. Dataset used is based on an actual 12-hour data gathering of charging cycle and current-voltage readings. Simulation results show that the developed system generated correctly the charge level of the battery using only the instantaneous voltage and current readings from the sensors.
html
Digitial Object Identifier (DOI)
10.1109/HNICEM48295.2019.9073361
Recommended Citation
Venancio, L. A., Sy, A. C., Bedruz, R., & Dadios, E. P. (2019). Development of charge level monitoring of lead-acid battery bank for PV system using fuzzy logic in LabView. 2019 IEEE 11th International Conference on Humanoid, Nanotechnology, Information Technology, Communication and Control, Environment, and Management, HNICEM 2019 https://doi.org/10.1109/HNICEM48295.2019.9073361
Disciplines
Mechanical Engineering
Keywords
Fuzzy logic; Computers—Circuits; Lead-acid batteries; Nanotechnology