Seismic vulnerability assessment of a historical structure: A case study of El Deposito Waterworks System
Date of Publication
2018
Document Type
Bachelor's Thesis
Degree Name
Bachelor of Science in Civil Engineering with Specialization in Structural Engineering
Subject Categories
Civil Engineering
College
Gokongwei College of Engineering
Department/Unit
Civil Engineering
Thesis Adviser
Lessandro Estelito O. Garciano
Defense Panel Chair
Andres Winston C. Oreta
Defense Panel Member
Jonathan R. Dungca
Adam C. Abinales
Abstract/Summary
Due to old age and the materials used during construction, a historical structure is deemed vulnerable to damages brought about by natural hazards. Being located within the Pacific ring of fire, the Philippines experiences numerous earthquakes and may pose as a significant threat to a historical structure. With the plan of the National Historical Commission of the Philippines to convert an underground tunnel into a museum, a seismic vulnerability assessment of the historical structure-- El Deposito Waterworks System in Pinaglabanan, San Juan City, was conducted, considering a possibility of an earthquake generated from the West Valley fault. The peak ground acceleration (PGA) and the response spectrum obtained using probabilistic seismic hazard analysis (PSHA) was used as input to a software to produce the time history for the nonlinear time history analysis, by matching the response spectrum with the 1978 Great Thessaloniki Earthquake. Finite element analysis was conducted for modelling the tunnel, with pinned supports and horizontal soil springs. Shear stresses for every scale of PGA from 0.1g to 0.4g from the analysis were compared with the shear capacity of the material comprising the structure based from Ampad, Castillo, Odiamar, Tingco and Garciano (2017) which is 1.71 MPa and the World of Engineering Organizations (2011) which is 0.1 MPa. Results showed that the shear stresses did not exceed the shear capacity, as the maximum shear stress experienced by an element after subjecting the structure to dead loads and an earthquake load of 0.4g PGA was found to be 0.08341 MPa. SInce failure did not occur upon application of a 0.4g PGA earthquake, the time history was further scaled to 2.0g PGA, resulting to a maximum shear stress of 0.9108 MPa, which did not exceed the shear capacity. The shear maximum stresses are found to have a direct relationship with the peak ground acceleration of the earthquake load, and which occur at the intersection of the arch and the inner wall of the tunnel while maximum displacement
Abstract Format
html
Language
English
Format
Accession Number
TU21635
Shelf Location
Archives, The Learning Commons, 12F, Henry Sy Sr. Hall
Physical Description
xii, 132 leaves : illustrations (some color) ; 30 cm.
Keywords
Structural engineering; Tunnels--Design and construction; El Deposito Waterworks System
Recommended Citation
Alberto, B., Apacible, P. M., Pacayra, A. B., & See, A. J. (2018). Seismic vulnerability assessment of a historical structure: A case study of El Deposito Waterworks System. Retrieved from https://animorepository.dlsu.edu.ph/etd_bachelors/9085